1简介编辑HTF系列消防高温排烟风机适用于高层建筑、地下建筑及隧道、烘房等通风换气或高温排烟。能在280℃高温条件下连续运转30分钟以上,介质温度100℃条件下连续运行20小时/次不损坏,是理想的消防必备设施。2性能和型号编辑1、[1]该风机的性能表中列出的性能是最高效率范围内的性能,按风量分为五个性能工况点,选用时按性能表为准。出厂的风机合格品是在额定风量下,全压值误差不超过 5%,性能选用表 是标准状态下的性能,无论技术文件或定货要求的性能均以标准状态为准;2、该风机安装方式可分为卧式和屋顶式,对风量、全压、安装尺寸等性能都有特殊要求;3、HTFⅠ、HTFⅡ表示常压型消防高温排烟专用风机,叶型采用轴流式:HTFⅠ(单速) 和HTFⅡ(双速)两种;HTFⅢ、HTFⅣ表示中压消防高温排烟专;4、 HTFX为消音型消防高温排烟专用风机,用户可根据实际需要选用不同的种类;5、HTFW系列屋顶式消防高温排烟专用风机,用户可根据实际需要选用阻燃型玻璃钢风帽或 钢制风帽;6、HTFD为低压型消防高温排烟专用风机;7、特别说明: GYF与HTF系列风机是同类产品。3风机参数编辑HTF-Ⅰ(Ⅱ)型(单、双速)性能参数机号转速(rpm)风量(m/h)风压(Pa)单速功率(kW)双速功率(kW)噪声dB(A)重量(Kg)429006500520046004104905201.51.9/0.4777614503250260023001021221300.5573694.529007900580050005105906702.22.5/0.65788814503950290025001271471670.7574805290098248861681751061075233.1/0.88011014504912443134101271531881.175965.5290015200120001090039859262144.4/1.18613514507600600054501001481551.575115629001609015102131975106107605.55.9/1.48616414508045755165991271531901.5751306.514502150018000153004256206805.56.7/2.2881809601423511918101301872722982.280165714502438022439189086106557287.59.5/3.188208960161411486512518267287319380189机号转速(rpm)风量(m/h)风压(Pa)单速功率(kW)双速功率(kW)噪声dB(A)重量(Kg)814503142129172260126006617237.59.5/3.189230960208001931417222263290317380211914503351032297275135626688401112/4902849602218621383182162462933684812301014504567940000350006306907701112/4883109603025526483240192763023385.5802651114505155250128485005806476901515.5/5.1923809603566437596363753263643875.5833351296062763593005565162468074018.517/8.59348072047072444754331135138341611834301396074708653705603160071080718.517/8.59452072056031490274202333839945411/84470159609380086115760416237108192222/11956507207035064586570313504104611185585注:双速风机重量参考同号中高速风机的重量。[1]4外形尺寸编辑机号D1D2D3M1M2M3M4L(Ⅰ型)L(Ⅱ型)n-14-2HH1ABB244104404703403802003005806008-8.512.5701040890600604.54604905203503902503506006408-8.512.530010608906506055105505803804203004006506508-8.512.532011201000700605.556060063047051040050068068010-10.512.53501150100075060661065069054058040050070070010-10.514.538011701000800606.566070074057061040050080080010-10.514.54101270122085080771075079057061050060080087010-10.514.54301270122095080881085089057061050060080087012-12.514.549013101340105080991095099058064060070086090012-12.516.5560137016501150801010101050109058064060070086090012-12.516.5610153016501250801111101160121058064070080090096014-12.516.5660159018001400100121210136013107308008009001200120014-12.516.57301650180015001001313101360141073080090010001200120016-12.518.576016501800160010015151015601610730800104012001200120018-12.518.5860165025001800100注:1、屋顶式风机基础高度应250mm。2、风机出厂时法兰一般不打孔,n-1仅供参考,若要打孔请用户在订货时说明。HTF型风机配带消声器外形尺寸表[配带图示消声器后风机可降噪约8-20dB(A)]5安装过程编辑1、全面熟悉风机的样本,熟悉风机的规格、形式、叶轮旋转方向和气流进出方向等等,风机安装前应检查叶轮有无擦碰现象,并对各部件进行全面检查,附件是否完整,各部件联接是否坚固、认真检查风叶是否因运输损坏或变形,否则应待修复后方可安装。2、联接风机进出口的风管应有单独的支撑,不允许将管道重量加在风机的部件上,风机安装时应注意风机的水平位置,对风机与地基的结合面和出风管道的联接应调整,使之自然吻合,不得强行联接。3、风机安装后,用手或杠杆拔动叶轮,检查是否有过紧或擦碰现象,有无妨碍转动的物品,无异常现象下,方可进行试运转,风机会传动装置的外露部分应有防护罩(用户自备)。如风机进风口不接管道时,也需添置防护网或其他安全装置(用户自备)。4、风机接线必须正确可靠,风机外壳应妥善接地,接地必须可靠。供给风机的电源必须完整,并符合相关要求。电气接线必须有专业知识的电工接线。